  1. ATS 400 Bild 1
    ATS400 UHGIPRF-507030L32
    Article number 211917
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring
    • HV DC - High Voltage Testing
      150,0 - 7000 V DC, 0,01 - 100,00 mA (opt. from 1 nA), max. 500VA, potential free, active discharge, ramp, discharge monitoring
    • ISO - Insulation Testing
      50,0 - 3000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 10 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring
    • PE - Testing of Protective Earth
      2,0 - 32,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, 4 - wire measurement
    • R - Resistance Measurement DC4
      1 µA - 2 A, 0,01 µΩ - 2,2000 MΩ, 4-wire measuring technique, contact monitoring, automatic measuring range selection, optional 11 fixed measuring ranges
    • FCT Mains - Function Measurement
      Mains Voltage, 10,00 A (opt. 16,00 A)
    • FCT variable - Function Measurement
      1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source
    • Contacting options
      CC, CNC
  2. ATS 400 Bild 1
    ATS400 LG-AC-CL
    Article number 209010
    • HV AC - High Voltage Testing
      100,0 - 4000 V AC, 0,01 - 2,50 mA (opt. from 1 nA), potential free, ramp, discharge monitoring
    • ISO - Insulation Testing
      50,0 - 1000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring
    • PE - Testing of Protective Earth
      2,0 - 25,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V, 4 - wire measurement
    • R - Continuity Testing DG1
      1 - 100 Ω
    • FCT Mains - Function Measurement
      Mains Voltage, 10,00 A (opt. 16,00 A)
    • FCT variable - Function Measurement
      1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source
    • Contacting options
      CCCG
  3. ATS 400 Bild 1
    ATS400 HG-DC
    Article number 201869
    • HV DC - High Voltage Testing
      50,0 - 3000 V DC, 0,01 - 2,00 mA, current limited, earthed on one side, active discharge, ramp, discharge monitoring
    • PE - Testing of Protective Earth
      2,0 - 25,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V, 4 - wire measurement
    • R - Continuity Testing DG1
      1 - 100 Ω
    • FCT Mains - Function Measurement
      Mains Voltage, 10,00 A (opt. 16,00 A)
    • FCT variable - Function Measurement
      1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source
    • Contacting options
      CCCG
  4. ATS 400 Bild 1
    ATS400 LG-DC
    Article number 201838
    • HV DC - High Voltage Testing
      50,0 - 3600 V DC, 0,01 - 2,00 mA, current limited, earthed on one side, active discharge, ramp, discharge monitoring
    • ISO - Insulation Testing
      50,0 - 1000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring
    • PE - Testing of Protective Earth
      2,0 - 25,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V, 4 - wire measurement
    • R - Continuity Testing DG1
      1 - 100 Ω
    • FCT Mains - Function Measurement
      Mains Voltage, 10,00 A (opt. 16,00 A)
    • FCT variable - Function Measurement
      1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source
    • Contacting options
      CCCG
  5. ATS 400 Bild 1
    ATS400 HG-AC
    Article number 206561
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring
    • PE - Testing of Protective Earth
      2,0 - 25,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V, 4 - wire measurement
    • R - Continuity Testing DG1
      1 - 100 Ω
    • FCT Mains - Function Measurement
      Mains Voltage, 10,00 A (opt. 16,00 A)
    • FCT variable - Function Measurement
      1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source
    • Contacting options
      CCCG
  6. ATS 400 Bild 1
    ATS400 HG-DCX
    Article number 201886
    • HV DC - High Voltage Testing
      50,0 - 3600 V DC, 0,01 - 2,00 mA, current limited, earthed on one side, active discharge, ramp, discharge monitoring
    • PE - Testing of Protective Earth
      2,0 - 25,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V, 4 - wire measurement
    • R - Continuity Testing DG1
      1 - 100 Ω
    • FCT Mains - Function Measurement
      Mains Voltage, 10,00 A (opt. 16,00 A)
    • FCT variable - Function Measurement
      1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source
    • Contacting options
      CCCG
  7. ATS 400 Bild 1
    ATS400 LG-L
    Article number 202136
    • ISO - Insulation Testing
      50,0 - 1000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring
    • PE - Testing of Protective Earth
      2,0 - 25,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V, 4 - wire measurement
    • R - Continuity Testing DG1
      1 - 100 Ω
    • FCT Mains - Function Measurement
      Mains Voltage, 10,00 A (opt. 16,00 A)
    • FCT variable - Function Measurement
      1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source
    • Contacting options
      CCCG
  8. ATS 400 Bild 1
    ATS400 LG-ACX
    Article number 204822
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free
    • ISO - Insulation Testing
      50,0 - 1000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring
    • PE - Testing of Protective Earth
      2,0 - 25,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V, 4 - wire measurement
    • R - Continuity Testing DG1
      1 - 100 Ω
    • FCT variable - Function Measurement
      1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source
    • Contacting options
      CCCG
  9. ATS 400 Bild 1
    ATS400 LG-LX
    Article number 202913
    • ISO - Insulation Testing
      50,0 - 1000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring
    • PE - Testing of Protective Earth
      2,0 - 25,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V, 4 - wire measurement
    • R - Continuity Testing DG1
      1 - 100 Ω
    • FCT Mains - Function Measurement
      Mains Voltage, 10,00 A (opt. 16,00 A)
    • FCT variable - Function Measurement
      1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source
    • Contacting options
      CCCG
  10. ATS 400 Bild 1
    ATS400 UHGIPRF-5030L30L32
    Article number 212557
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring
    • HV DC - High Voltage Testing
      50,0 - 3000 V DC, 0,01 - 2,00 mA, active discharge, ramp, discharge monitoring
    • ISO - Insulation Testing
      50,0 - 3000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring
    • PE - Testing of Protective Earth
      2,0 - 32,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, 6 - 12 V, 4 - wire measurement
    • R - Resistance Measurement DC4
      1 µA - 2 A, 0,01 µΩ - 2,2000 MΩ, 4-wire measuring technique, contact monitoring, automatic measuring range selection, optional 11 fixed measuring ranges
    • FCT Mains - Function Measurement
      Mains Voltage, 10,00 A (opt. 16,00 A)
    • FCT variable - Function Measurement
      1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source