By Test Types
-
ATS400 UGIR-7030LArticle number 211647
- HV DC - High Voltage Testing
150,0 - 7000 V DC, 0,01 - 100,00 mA (opt. from 1 nA), max. 500VA, potential free, ramp, discharge monitoring - ISO - Insulation Testing
50,0 - 3000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), earthed on one side, active discharge, ramp, discharge monitoring - R - Resistance Measurement DC4
1 µA - 2 A, 0,01 µΩ - 2,2000 MΩ, 4-wire measuring technique, contact monitoring, automatic measuring range selection, optional 11 fixed measuring ranges - Contacting options
CCC
- HV DC - High Voltage Testing
-
ATS400 UHGIPRFA-507030L32Article number 212183
- HV AC - High Voltage Testing
100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring - HV DC - High Voltage Testing
150,0 - 7000 V DC, 0,10 - 100 mA, potential free, active discharge, ramp, discharge monitoring - ISO - Insulation Testing
50,0 - 3000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring - PE - Testing of Protective Earth
2,0 - 32,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V - R - Resistance Measurement DC4
1 µA - 2 A, 0,01 µΩ - 2,2000 MΩ, 4-wire measuring technique, contact monitoring, automatic measuring range selection, optional 11 fixed measuring ranges - FCT variable - Function Measurement
1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source - AI - Leakage Current Testing
0,1 µA - 30,00 mA, 0 - 1 MHz, EN 60601-1 (medical), EN 60990-1 (industrial), opt. other standards - Contacting options
CCCG
- HV AC - High Voltage Testing
-
ATS400 UGI-36L36L, current limitedArticle number 211751
- HV AC - High Voltage Testing
100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring - HV DC - High Voltage Testing
50,0 - 3000 V DC, 0,01 - 2,00 mA, current limited, earthed on one side, active discharge, ramp, discharge monitoring - PE - Testing of Protective Earth
2,0 - 32,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V, 4 - wire measurement - Contacting options
CCG
- HV AC - High Voltage Testing
-
ATS400 UHR-50Article number 208003
- HV AC - High Voltage Testing
100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring - R - Resistance Measurement DC4
1 µA - 2 A, 0,01 µΩ - 2,2000 MΩ, 4-wire measuring technique, contact monitoring, automatic measuring range selection, optional 11 fixed measuring ranges - Contacting options
CCC
- HV AC - High Voltage Testing
-
ATS400 UGIPR-707032Article number 211718
- HV DC - High Voltage Testing
150,0 - 7000 V DC, 0,10 - 100 mA, potential free, ramp, discharge monitoring - ISO - Insulation Testing
150,0 - 7000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), potential free, ramp, discharge monitoring - PE - Testing of Protective Earth
2,0 - 32,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V - R - Resistance Measurement DC4
1 µA - 2 A, 0,01 µΩ - 2,2000 MΩ, 4-wire measuring technique, contact monitoring, automatic measuring range selection, optional 11 fixed measuring ranges - Contacting options
CCCG
- HV DC - High Voltage Testing
-
ATS400 UG-50LArticle number 205929
- HV DC - High Voltage Testing
150,0 - 5000 V DC, 0,01 - 5,00 mA, current limited, potential free, ramp, discharge monitoring - Contacting options
CC
- HV DC - High Voltage Testing
-
ATS400 UG-30LArticle number 202846
- HV DC - High Voltage Testing
50,0 - 3000 V DC, 0,01 - 2,00 mA, current limited, earthed on one side, active discharge, ramp, discharge monitoring - Contacting options
CC
- HV DC - High Voltage Testing
-
ATS400 UGI-36L36L, current limitedArticle number 204674
- HV AC - High Voltage Testing
100,0 - 6000 V AC, 0,01 - 80,00 mA, potential free, ramp, discharge monitoring - PE - Testing of Protective Earth
2,0 - 32,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V, 4 - wire measurement - Contacting options
CCG
- HV AC - High Voltage Testing
-
ATS400 UGI-36L36L, current limitedArticle number 212475
- HV DC - High Voltage Testing
50,0 - 3600 V DC, 0,01 - 2,00 mA, current limited, earthed on one side, active discharge, ramp, discharge monitoring - PE - Testing of Protective Earth
2,0 - 32,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, < 12 V, 4 - wire measurement - Contacting options
CCG
- HV DC - High Voltage Testing
-
ATS400 UHGI-507030LeArticle number 211988
- HV AC - High Voltage Testing
100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring - HV DC - High Voltage Testing
150,0 - 7000 V DC, 0,01 - 100,00 mA (opt. from 1 nA), max. 500VA, potential free, ramp, discharge monitoring - ISO - Insulation Testing
50,0 - 3000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring - Contacting options
CC
- HV AC - High Voltage Testing