ATS400 UGI-3030-1GArticle number 210277
- HV DC - High Voltage Testing
150,0 - 3000 V DC, 0,01 - 100,00 mA (opt. from 1 nA), max. 500VA, potential free, ramp, discharge monitoring - ISO - Insulation Testing
150,0 - 3000 V DC, 500,0 kΩ - 1000 MΩ (opt. 5 GΩ), active discharge, potential free, ramp, discharge monitoring - Contacting options
CC
- HV DC - High Voltage Testing
-
ATS400 UGI-36L36L, current limitedArticle number 211858
- HV AC - High Voltage Testing
100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring - HV DC - High Voltage Testing
150,0 - 7000 V DC, 0,01 - 100,00 mA (opt. from 1 nA), max. 500VA, potential free, ramp, discharge monitoring - ISO - Insulation Testing
50,0 - 3000 V DC, 500,0 kΩ - 1000 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, ramp, discharge monitoring - Contacting options
CC
- HV AC - High Voltage Testing
-
ATS400 UGI-36L36L, current limitedArticle number 211715
- HV AC - High Voltage Testing
100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring - HV DC - High Voltage Testing
50,0 - 3000 V DC, 0,01 - 2,00 mA, current limited, earthed on one side, active discharge, ramp, discharge monitoring - ISO - Insulation Testing
50,0 - 3000 V DC, 500,0 kΩ - 1000 MΩ (opt. 5 GΩ), earthed on one side, active discharge, ramp, discharge monitoring - PE - Testing of Protective Earth
2,0 - 32,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, 6 - 12 V, 4 - wire measurement - Contacting options
CCG
- HV AC - High Voltage Testing
-
ATS400 UGI-36L36L, current limitedArticle number 205820
- HV DC - High Voltage Testing
50,0 - 3600 V DC, 0,01 - 2,00 mA, current limited, earthed on one side, active discharge, ramp, discharge monitoring - ISO - Insulation Testing
50,0 - 3600 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring - Contacting options
CC
- HV DC - High Voltage Testing
-
ATS400 machinery testerArticle number 201903
- HV AC - High Voltage Testing
100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring - ISO - Insulation Testing
50,0 - 1000 V DC, 500,0 kΩ - 1000 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring - PE - Testing of Protective Earth
2,0 - 25,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, 6 - 12 V, 4 - wire measurement - Contacting options
CCG
- HV AC - High Voltage Testing
-
ATS400 UHGIR-507070Article number 211360
- HV AC - High Voltage Testing
100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring - HV DC - High Voltage Testing
150,0 - 7000 V DC, 0,01 - 100,00 mA (opt. from 1 nA), max. 500VA, potential free, ramp, discharge monitoring - ISO - Insulation Testing
150,0 - 7000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 10 GΩ), potential free, ramp, discharge monitoring - R - Resistance Measurement DC4
1 µA - 2 A, 0,01 µΩ - 2,2000 MΩ, 4-wire measuring technique, contact monitoring, automatic measuring range selection, optional 11 fixed measuring ranges - Contacting options
CCC
- HV AC - High Voltage Testing
-
ATS400 UH-50Article number 202036
- HV AC - High Voltage Testing
100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring - Contacting options
CC
- HV AC - High Voltage Testing
-
ATS400 LG-DCXArticle number 201811
- HV DC - High Voltage Testing
50,0 - 3600 V DC, 0,01 - 2,00 mA, current limited, earthed on one side, active discharge, ramp, discharge monitoring - ISO - Insulation Testing
50,0 - 1000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring - PE - Testing of Protective Earth
2,0 - 25,0 A AC/DC (opt. up to 40 A), 1 - 500 mΩ, 6 - 12 V, 4 - wire measurement - R - Continuity Testing DG1
1 - 100 Ω - FCT Mains - Function Measurement
Mains Voltage, 10,00 A (opt. 16,00 A) - FCT variable - Function Measurement
1,0 - 270,0 V AC, 45- 65 Hz, 500 VA, electronic source - Contacting options
CCCG
- HV DC - High Voltage Testing
-
ATS400 UGI-7030LArticle number 210424
- HV DC - High Voltage Testing
150,0 - 7000 V DC, 0,01 - 100,00 mA (opt. from 1 nA), max. 500VA, potential free, ramp, discharge monitoring - ISO - Insulation Testing
50,0 - 3000 V DC, 500,0 kΩ - 1000 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring - Contacting options
CC
- HV DC - High Voltage Testing
-
ATS400 UGI-36L36L, current limitedArticle number 211137
- HV AC - High Voltage Testing
100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring - HV DC - High Voltage Testing
150,0 - 7000 V DC, 0,01 - 100,00 mA (opt. from 1 nA), max. 500VA, potential free, ramp, discharge monitoring - ISO - Insulation Testing
150,0 - 7000 V DC, 500,0 kΩ - 400,0 MΩ (opt. 10 GΩ), potential free, ramp, discharge monitoring - Contacting options
CC
- HV AC - High Voltage Testing